Interactive Concept
GP
Georgia-Pacific Building Products
GP-CHS-01 Download PDF

Steel-Framed Chase Wall

Double-row steel stud assembly designed for utility chases, plumbing walls, and HVAC enclosures. Provides 1-hour fire resistance with excellent acoustic performance.

1-HR
Fire Rating
45-49
STC Rating
5½"
Thickness
Assembly Detail
Fire-Design
24" O.C. 5-1/2"
Sound Design
24" O.C. 5-1/2"
5/8" Gypsum Panel
1-5/8" Steel Stud
5/8" Gypsum Bracing
3-1/2" Insulation
🖱️ Drag to rotate • Scroll to zoom • Right-drag to pan
PBR SSAO HDR
View
Components

Key Specifications

Required
Stud Size 1-5/8" (41mm)
Stud Spacing 24" O.C.
Row Gap 1" min
Steel Gauge 15 mil min

Fastener Schedule

Edge Spacing 8" O.C.
Field Spacing 12" O.C.
Screw Type 1" Type S

Design References

UL U420 GA WP 5041 NOAL 17-0821
Approved Products
ToughRock® Fireguard X®
DensArmor Plus® Fireguard®
DensGlass® Fireguard®
DensElement® Barrier
DensShield® Fireguard®
DensDeck® Fireguard®
ToughRock® Lite-Weight
DensDeck® StormX® Prime
Installation Requirements
1 Framing Requirements
Install double row of 1-5/8" (41mm) steel studs at 24" O.C. with minimum 1" (25mm) gap between rows. Use 15 mil minimum gauge steel.
2 Cross Bracing
5/8" gypsum board pieces 9-1/2" × 12" fastened to back of studs with three Type S wallboard screws per stud. Maximum vertical spacing 48" O.C. Alt: steel runner min 4-1/4" with two No. 8 × 1/2" self-drilling screws.
3 Gypsum Application
Apply 5/8" gypsum panels parallel to studs using 1" Type S screws at 8" O.C. on edges and 12" O.C. at intermediate studs. Stagger joints 24" on opposite sides.